Tank Cleaning Nozzles and Equipment Selection Guide

Find the proper tank cleaning equipment for your operation by evaluating the wide range
tank cleaners and nozzles available from Spraying Systems Co.
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 4 Tank Cleaning Nozzle
TankJet® 360
100' (30m)
Fluid Driven
Turbine
40 - 350
(2.8 - 24)
30 - 300
(113.5 - 1135.6)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
6.25
(158.7)
250
(121)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 700
TankJet 700
100' (30m)
Fluid Driven
Turbine
40 - 350
(2.8 - 24)
30 - 300
(113.5 - 1135.6)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
7
(178)
250
(121)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 750 Tank Cleaning Nozzle
TankJet 750
100' (30m)
Fluid Driven
Turbine
40 - 350
(2.8 - 24)
30 - 300
(113.5 - 1135.6)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
10.25
(260)
250
(121)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 180 Tank Cleaning Nozzle
TankJet 180
80' (24.4m)
Fluid Driven
Turbine
40 - 350
(2.8 - 24)
30 - 300
(113.5 - 1135.6)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
180 degrees down
180°
12.25
(311)
250
(121)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
AA290AG Tank Cleaner
TankJet AA290
80' (24.4m)
Motor Driven
50 - 250
(3.5 - 17)
22 - 200
(85 - 757)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
7.25 (184)
for 2 nozzle;
8.25 (210)
for 4 nozzle
200
(93)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 80 Tank Cleaning Spray Nozzle
TankJet 80
50' (15.2m)
Fluid Driven
Turbine
60 - 150
(4.1 - 10.3)
50 - 125
(189 - 473)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
6.5 (165)
for 2 nozzle;
12.5 (318)
for 3 nozzle
250
(121)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 65 Tank Cleaning Spray Nozzle
TankJet 65
40' (12.2m)
Fluid Driven
Turbine
50 - 150
(3.4 - 10.3)
30 - 150
(114 - 568)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
7.5
(190)
250 (121);
500 (260)
high-temperature
version
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
AA190AGH Tank CleanerAA190D Tank Cleaner
TankJet AA190
34' (10.4m)
Motor Driven
100 - 1000
(7 - 70)
3.1 - 44
(11.8 - 170)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
180 degrees down 360 degrees
180° down
360°
3.75 (95)
for 360°;
4.5 (114.3)
for 180°
200
(93)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 75 Fluid Driven Tank Cleaning Nozzle
TankJet 75
30' (9.1m)
Fluid Driven
50 - 300
(3.5 - 20.7)
8 - 33
(30 - 125)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
3 (76.2)
for 2 nozzle;
3.75 (95.2)
for 4 nozzle
250
(121)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
Fluid Driven Reactionary
Force
10 - 50
(0.7 - 3.5)
4 - 391
(15.3 - 1490)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
180 degrees up 180 degrees down
270 degrees up 270 degrees down
360 degrees
180° up/down 270° up/down 360°
2 - 7
(51 - 178)
200
(93)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 14 Tank Cleaning Nozzle
TankJet 14
24' (7.2m)
Fluid Driven
Turbine
50 - 200
(3.4 - 13.8)
13 - 34
(49 - 129)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
  180 degrees up 180 degrees down
 270 degrees down 360 degrees
180° up/down, 270° down
2
(51)
250
(121)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 16 Tank Cleaning Nozzle
TankJet 16
24' (7.2m)
Fluid Driven
Turbine
50 - 200
(3.4 - 13.8)
30 - 76
(114 - 288)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
  180 degrees up 180 degrees down
 270 degrees down 360 degrees
180° up/down, 270° down
3
(76)
250
(121)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
12900 Tank Cleaning Nozzle
TankJet 12900
22' (6.7m)
Fixed Stationary
20 - 50
(1.5 - 3.5)
72 - 385
(280 - 1470)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360° and custom spray angles
10


(254)
212
(100)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
Fluid Driven
Constant Speed
30 - 230
(2 - 16)
3.2 - 31
(12 - 128)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
65 degrees down 120 degrees down
180 degrees up 180 degrees down
 270 degrees down
360 degrees
65° down, 120° down, 180° up/down, 260° up/down, 360°up/down, 360°
2.25


(56)
160
(70)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
Fluid Driven Reactionary Force
10 - 50
(0.7 - 3.5)
9 - 78
(34 - 295)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
180 degrees up 180 degrees down
270 degrees up 270 degrees down
360 degrees
180° up/down 270° up/down 360°
2.5 - 4
(64 - 102)
200
(93)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 9 Tank Cleaning Nozzles
TankJet 9
16' (4.9m)
Fluid Driven Reactionary Force
10 - 120
(0.7 - 8.3)
TJ9-A:
1.3 - 5
(4.9 - 18.9)
TJ9-B:
5 - 17
(18.9 - 64)
TJ9-C:
12 - 38
(45 - 144)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
180 degrees up 180 degrees down
360 degrees
2 x 175°
360°
TJ9-A: 1.0625
(27)
TJ9-B:
1.375 (35)
TJ9-C:
1.625
(42)
190
(88)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
63225 Fixed Spray Tank Cleaning Balls
TankJet 63225
13' (4m)
Fixed Stationary
15 - 40
(1-2.8)
22 - 51
(83 - 192)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
1.5 - 4
(38 - 102)
400
(204)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 19 Tank Cleaning Nozzle
TankJet 19
12' (3.6m)
Fluid Driven Stationary
50 - 200
(3.4 - 13.8)
10 - 30
(38 - 114)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
180 degrees up 180 degrees down
 270 degrees down 360 degrees
180° up/down 270° down 360°
2.0
(51)
250
(121)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
D41800E Fluid Driven Constant Speed Tank Cleaning Nozzle
TankJet D41800E
12' (3.6m)
Fluid Driven Constant Speed
30 - 230
(2 - 16)
2.7 - 33
(12 - 128)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
1.25 (32)


300
(150)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
Fixed Stationary
20 - 50
(1.5 - 3.5)
8.9 - 80
(35 - 301)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
6 (152)
212
(100)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
AA090 Tank Cleaner
TankJet AA090
8' (2.4m)
Motor Driven
100 - 500
(7 - 35)
1.5 - 7.3
(5.7 - 28)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
2.3 (59)


200
(93)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
30473 Tank Cleaning Spray Nozzle
TankJet 30473
8' (2.4m)
Fluid Driven Reactionary Force
10 - 50
(0.7 - 4)
2.1 - 4.5
(7.8 - 18)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
180 degrees up 180 degrees down360 degrees
180° up/down~360°
1 (25)


200
(93)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
18250A Tank Cleaning Nozzle
TankJet 18250A
8' (2.4m)
Fluid Driven Reactionary Force
10 - 60
(1 - 4)
10.5 - 55
(48 - 205)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
2.22 (60)
350
(177)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
D41892 Fluid Driven Reactionary Force Tank Cleaning Spray Nozzle
TankJet D41892
6.5' (2.0m)
Fluid Driven Reactionary Force
20 - 70
(1.4 - 5)
4.0 - 7.5
(15.9 - 29)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
1.5 (37)


160
(70)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
D41990 Tank Cleaning Nozzle
TankJet D41990
6.5' (2.0m)
Fluid Driven Reactionary Force
15 - 60
(1 - 4)
2.5 - 7.3
(9.5 to 28)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
180 degrees up 180 degrees down360 degrees
180° up/down
360°
Thread:
1 (25)
CIP version:
2 (50)
300
(149)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 55
TankJet 55
5' (1.5m)
Fluid Driven Reactionary Force
200 - 1000 (13.8 - 69)
3 - 8
(11 - 30)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
1-3/4
(44.5)
200
(93)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
VSM Tank Cleaning Nozzle
TankJet VSM
5' (1.5m)
Fixed Stationary
10 - 150
(0.7 - 10)
2.7 - 72
(10.4 - 269)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
210 degrees
240° down
2 (51)


200
(93)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
21400A Fluid Driven Reactionary Force Tank Cleaning Nozzle
TankJet 21400A
5' (1.5m)
Fluid Driven Reactionary Force
10 - 60
(1 - 4)
5 - 22
(23 - 82)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360 degrees
360°
2.25
(60)
350
(177)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
3150 Tank Cleaning Nozzle
TankJet 31500
3' (0.0m)
Fixed Stationary
10 - 150
(1 - 10)
5.2 - 26
(23 - 91)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
210 degree spray 360 degrees
210° , 360°
2 (51)


212
(100)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 36640 Fluid Driven Reactionary Force Tank Cleaning Nozzle
TankJet 36640
3' (0.0m)
Fluid Driven Reactionary Force
10 - 60
(1 - 4)
0.8 - 2.2
(3.4 - 7.9)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
Side Spray
Side Spray
1.03
(26)
200
(93)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
TankJet 23240 Tank Cleaning Nozzle
TankJet 23240
3' (0.0m)
Fluid Driven Reactionary Force
20 - 200
(1.5 - 12)
3.5 - 22
(14 - 79)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
360
Side Spray
360°, Side Spray
1.03 (26)
350
(177)
Nozzle/
Max Tank Dia. ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
15498 Tank Cleaning Nozzle
TankJet 15498
2' (0.6m)
Fixed Stationary
60 - 150
(5 - 10)
5.5 - 11.7
(23 - 43)
Spray Coverage
Min Tank Opening Size In (mm)
Max Temperature °F (°C)
210 degree spray 360 degrees
210°, 360°
2
(51)
212
(100)

Tank Cleaning Nozzles and Equipment Selection Guide

Find the proper tank cleaning equipment for your operation by evaluating the wide range
tank cleaners and nozzles available from Spraying Systems Co.
Nozzle
Max Tank Diameter
ft (m)
Operating Principle
Operating Pressure
psi (bar)
Flow Rate Range
gpm (l/min)
Spray Coverage
Min Tank Opening Size
in (mm)
Max Temperature
°F (°C)
100 (30)
Fluid Driven Turbine
40 - 350
(2.8 - 24)
30 - 300
(113.5 - 1135.6)
360 degrees
360°
6.25
(158.7)
250
(121)
80 (24.4)
Fluid Driven Turbine
40 - 350
(2.8 - 24)
30 - 300
(113.5 - 1135.6)
180 degrees down
180°
12.25
(311)
250
(121)
Motor Driven
50 - 250
(3.5 - 17)
22 - 200
(85 - 757)
360 degrees
360°
7.25 (184)
for 2 nozzle;
8.25 (210)
for 4 nozzle

200
(93)

50 (15.2)
Fluid Driven
Turbine
60 - 150
(4.1 - 10.3)
50 - 125
(189 - 473)

360 degrees
360°

6.5 (165)
for 2 nozzle;
12.5 (318)
for 3 nozzle
250
(121)
40 (12.2)
Fluid Driven
Turbine
50 - 150
(3.4 - 10.3)
30 - 150
(114 - 568)

360 degrees
360°

7.5
(190)
250 (121);
500 (260)
high-temperature
version
34 (10.4)
Motor Driven
100 - 1000
(7 - 70)
3.1 - 44
(11.8 - 170)

180 degrees down 360 degrees
180° down
360°

3.75 (95)
for 360°;
4.5 (114.3)
for 180°
200
(93)
30 (9.1)
Fluid Driven
50 - 300
(3.5 - 20.7)
8 - 33
(30 - 125)

360 degrees
360°

3 (76.2)
for 2 nozzle;
3.75 (95.2)
for 4 nozzle
350
(121)
25 (7.6)
Fluid Driven Reactionary Force
10 - 50
(0.7 - 3.5)
4 - 391
(15.3 - 1490)
180 degrees up 180 degrees down
270 degrees up 270 degrees down
360 degrees
180° up/down 270° up/down 360°
2 - 7
(51 - 178)
200
(93)
TankJet 14 Tank Cleaning Nozzle
TankJet 14
24 (7.2) Fluid Driven Turbine 50 - 200
(3.4 - 13.8)
13 - 34
(49 - 129)
  180 degrees up 180 degrees down
 270 degrees down 360 degrees
180° up/down, 270° down, 360°
2
(51)
250
(121)
TankJet 16 Tank Cleaning Nozzle
TankJet 16
Fluid Driven Turbine 50 - 200
(3.4 - 13.8)
30 - 76
(114 - 288)
  180 degrees up 180 degrees down
 270 degrees down 360 degrees
180° up/down, 270° down, 360°
3
(76)
250
(121)
22 (6.7)
Fixed Stationary
20 - 50
(1.5 - 3.5)
72 - 385
(280 - 1470)
360 degrees
360° and custom spray angles

10

(254)

212
(100)
20 (6.0)
Fluid Driven Constant Speed
30 - 230
(2 - 16)
3.2 - 31
(12 - 128)
65 degrees down 120 degrees down
180 degrees up 180 degrees down
 270 degrees down
360 degrees
65° down, 120° down, 180° up/down, 260° up/down, 360°

2.25

(56)

160
(70)
18 (5.5)
Fluid Driven Reactionary Force
10 - 50
(0.7 - 3.5)
9 - 78
(34 - 295)
180 degrees up 180 degrees down
270 degrees up 270 degrees down
360 degrees
180° up/down 270° up/down 360°
2.5 - 4
(64 - 102)
200
(93)
TankJet 9 Tank Cleaning Nozzles
TankJet 9
16 (4.9) Fluid Driven Reactionary Force 10 - 120
(0.7 - 8.3)

TJ9-A:

1.3 - 5
(4.9 - 18.9)
TJ9-B:

5 - 17
(18.9 - 64)
TJ9-C:

12 - 38
(45 - 144)

180 degrees up180 degrees down
360 degrees

2 x 175°
360°

TJ9-A: 1.0625
(27)
TJ9-B:
1.375 (35)
TJ9-C:
1.625
(42)
190
(88)
13 (4)
Fixed Stationary
15 - 40
(1-2.8)
22 - 51
(83 - 192)
360 degrees
360°
1.5 - 4
(38 - 102)
400
(204)

TankJet 19 Tank Cleaning Nozzle
TankJet 19
12 (3.6)
Fluid Driven Stationary 50 - 200
(3.4 - 13.8)
10 - 30
(38 - 114)
180 degrees up 180 degrees down
 270 degrees down 360 degrees
180° up/down 270° down 360°
2.0
(51)
250
(121)
Fluid Driven Constant Speed
30 - 230
(2 - 16)
2.7 - 33
(12 - 128)
360 degrees
360°
1.25 (32)
300
(150)
10 (3.0)
Fixed Stationary
20 - 50
(1.5 - 3.5)
8.9 - 80
(35 - 301)
360 degrees
360°
6 (152)
212
(100)
8 (2.4)
Motor Driven
100 - 500
(7 - 35)
1.5 - 7.3
(5.7 - 28)
360 degrees
360°
2.3 (59)
200
(93)
Fluid Driven Reactionary Force
10 - 50
(0.7 - 4)
2.1 - 4.5
(7.8 - 18)
180 degrees up 180 degrees down360 degrees
180° up/down~360°
1 (25)
200
(93)
Fluid Driven Reactionary Force
10 - 60
(1 - 4)
10.5 - 55
(48 - 205)
360 degrees
360°
2.22 (60)
350
(177)
D41892 Fluid Driven Reactionary Force Tank Cleaning Spray Nozzle
TankJet D41892
6.5 (2.0)
Fluid Driven Reactionary Force 20 - 70
(1.4 - 5)
4.0 - 7.5
(15.9 - 29)
360 degrees
360°
1.5 (37) 160
(70)
D41990 Tank Cleaning Nozzle
TankJet D41990
Fluid Driven Reactionary Force
15 - 60
(1 - 4)
2.5 - 7.3
(9.5 to 28)
180 degrees up 180 degrees down360 degrees
180° up/down
360°
Thread:
1 (25)
CIP version:
2 (50)
300
(149)
TankJet M60
TankJet M60
5 (1.5)
Motor Driven 100 - 1000 (7 - 70) 1.1 - 10.1
(4.2 - 38.3)
360 degrees
360°
1-3/4
(44.5)
180
(82)
Fixed Stationary
10 - 150
(0.7 - 10)
2.7 - 72
(10.4 - 269)
210 degrees
240° down
2 (51)
200
(93)
Fluid Driven Reactionary Force
10 - 60
(1 - 4)
5 - 22
(23 - 82)
360 degrees
360°
2.25 (60)
350
(177)
3 (0.9)
Fixed Stationary
10 - 150
(1 - 10)
5.2 - 26
(23 - 91)
210 degree spray 360 degrees
210° , 360°
2 (51)
212
(100)
Fluid Driven Reactionary Force
10 - 60
(1 - 4)
0.8 - 2.2
(3.4 - 7.9)
Side Spray
Side Spray
1.03 (26)
200
(93)
Fluid Driven Reactionary Force
20 - 200
(1.5 - 12)
3.5 - 22
(14 - 79)
360
Side Spray
360°, Side Spray
1.03 (26)
350
(177)
2 (0.6)
Fixed Stationary
60 - 150
(5 - 10)
5.5 - 11.7
(23 - 43)
210 degree spray 360 degrees
210°, 360°
2 (51)
212
(100)